Leave Your Message

T2 Copper Busbar for Transformers

T2 Copper Busbar for Transformers, Low Voltage Lead-Out & Winding Connection, Tin-Plated/Bare/Custom Fabrication, High Conductivity

Application Scenarios:
- Oil-immersed/dry-type transformers: Low-voltage lead-out busbars, winding lead-out wires, neutral point connections, and grounding busbars.

- Box-type substations (European/American style): Connection between high-low voltage cabinets and transformers for long-term outdoor operation.

- PV/wind power transformers: High-current busbars for inverter side, withstanding high frequency and inrush current.

- Industrial special transformers: Kiloampere-level DC busbars for smelting and electrolysis transformers.

    T2 Copper Busbar for Transformers
    The technical specification for copper busbar:
    Parameter Item Parameter Value
    Material Grade T2 (TMY Copper Busbar)
    Copper Purity ≥99.95%
    Electrical Conductivity (20℃) ≥58.5 MS/m (97% IACS)
    Tensile Strength (Hard Temper) ≥295 MPa
    Elongation (Soft Temper) ≥40%
    Tin Coating Thickness (Tin-Plated Type) 5–10 μm (15μm customizable)
    Standard Sizes (Width × Thickness) 30×3, 40×4, 50×5, 60×6, 80×8, 100×10 mm; Length customizable (3m/6m/custom)
    Insulation Class Compatibility Class F (155℃), Class H (180℃)
    Contact Resistance (After Crimping) ≤10 μΩ
    Executive Standard GB/T 5585.1-2019, IEC 60228
    Selection Guide & Installation Recommendations:
    01
    Specification Calculation Determine the cross-section based on rated current, ambient temperature, and cooling method. Reduce current-carrying capacity by 10–15% for dry/closed environments. Example: 1000A usually uses 60×6 mm (360 mm²) busbar.
    02
    Surface Treatment Selection Bare copper for indoor dry environments; tin-plated (preferred) for humid/outdoor/coastal areas; silver-plated for high-frequency and precision applications.
    03
    Customization Process Provide drawings/current/transformer model → Quotation → Confirm process → Production → Quality inspection → Delivery.
    Application Scenarios
    Oil-immersed/dry-type transformers: Low-voltage lead-out busbars, winding lead-out wires, neutral point connections, and grounding busbars.
    Box-type substations (European/American style): Connection between high-low voltage cabinets and transformers for long-term outdoor operation.
    PV/wind power transformers: High-current busbars for inverter side, withstanding high frequency and inrush current.
    Industrial special transformers: Kiloampere-level DC busbars for smelting and electrolysis transformers.
    包装发货.png