How to Select Suitable Copper Foil Busbar for Lithium Battery PACK of Electric Forklifts & AGV Warehouse Robots?
2026-10-12
How to Select Suitable Copper Foil Busbar for Lithium Battery PACK of Electric Forklifts & AGV Warehouse Robots?
1. Confirm Electrical Parameters
- Rated continuous current and peak current Electric forklifts and AGVs work under low voltage & high current conditions, commonly DC48V/80V. Continuous current ranges from 300–600A, and instantaneous peak current can reach 800A during heavy-load startup. The cross-section of copper foil is determined by continuous current instead of peak current, with steady-state temperature rise as key evaluation index. Thinner 0.05mm foil offers better flexibility for compact PACK.
- Voltage and insulation withstand voltage Low-voltage lithium PACK usually requires insulation withstand voltage ≥3kV. Flame-retardant EVA heat shrink tube is widely used for flexible sections; TPE tube is an upgrade option for high-temperature warehouse. The two welded terminals are exposed for bolt connection.
2. Mechanical Structure & Dimension Selection
- Length of flexible section The flexible section absorbs cell expansion and vibration, minimum recommended length ≥40mm. Too short flexible segment cannot compensate displacement and may pull cell terminals. Copper foil busbar is only for unidirectional plane bending. Copper braid should be selected if torsion exists.
- Thickness of single copper foil 0.05mm T2 copper foil is preferred for forklift & AGV PACK for outstanding flexibility. T2 copper (C11000, Cu≥99.95%) ensures low resistivity.
- Terminals and mounting holes Confirm total length, terminal width, stacked thickness, hole diameter and hole pitch. Terminals are formed by polymer diffusion welding without cold solder joint. Common mounting holes: Φ8.5 for M8 bolt, Φ10.5 for M10 bolt.
3. Surface Treatment
- Full tin plating: mainstream choice for indoor warehouse, anti-oxidation and dust corrosion, cost-effective.
- Nickel plating: high salt spray and high temperature resistance, suitable for humid or port warehouses.
- Bare copper: only for dry sealed environment, easy to oxidize, not recommended.
4. Working Environment Evaluation
The products must pass vibration test to withstand frequent bump and impact. Operating temperature: -20℃~+55℃. Conductivity attenuation shall be less than 2% after 500 thermal cycles. Flat laminated structure avoids dust accumulation compared with copper braid.
5. Common Pitfalls in Selection
- Only calculate cross-section while ignoring flexible length, leading to terminal stress damage.
- Adopt brazing instead of diffusion welding, causing overheating on terminals.
- Apply copper foil busbar under torsional condition, resulting in foil delamination.
- Improper insulation tube selection causes aging and short circuit risk.
Xi'an Zipeng Technology provides one-stop customized service including selection, sample testing and mass delivery based on PACK drawings, current and vibration conditions.